By adding the internal
I/P module, the base model V100P, is quickly converted
to an electropneumatic positioner-at time of order
or in the field-simple and effective. The I/P module
is fed supply pressure air through specially designed
filters, and uses a 4-20mA analog signal to convert
this supply air to a 3-15 signal for mechanical
positioner response. This also means that troubleshooting
this product is simple and the I/P module can be
replaced while mounted on the actuator. An I/P conversion
kit would include the I/P module and terminal board,
an o-ring to seal the board, a screw to secure the
board, and a special stainless steel 1/4”
plug for plugging (tightly) the I/P port on the
gauge block. (Items 3,18, 20, and 41 of spare parts) |
|
|
 |
 |
 |
|
|